NEW CUMMINS C3000D6E GENERATOR SETS

3 MW Cummins Generators for Data Centers & Critical Power

Incoming Cummins C3000D6E diesel generator sets provide large-scale capacity for data centers, AI infrastructure, industrial facilities and other critical-power projects.

10 Units | 30 MW Aggregate Standby Capacity | Incoming Fall 2027

3000 kW Standby | 2750 kW Data Center Continuous | 277/480V | 3-Phase | 60 Hz | QSK95-G9 Diesel

Nationwide project support for data center and critical-power applications.

COMPREHENSIVE DATA CENTER SOLUTIONS

Large-Scale Generator Capacity for Data Center Projects

CI Group has 10 new Cummins C3000D6E QSK95-G9 diesel generator sets incoming for Fall 2027. Available for evaluation individually or as part of a multi-unit project, the equipment represents up to 30 MW of aggregate standby-rated generator capacity.

For data centers and other critical-power facilities, generator selection should be coordinated with required load, operating profile, redundancy, voltage, electrical architecture and project schedule.

Each C3000D6E is published by Cummins at:

Final project capacity should be based on the rating applicable to the intended operating profile.

Cummins C3000D6E Generator Specifications

ManufacturerCummins
ModelC3000D6E
EngineQSK95-G9 Diesel
Standby Rating3000 kW / 3750 kVA
Data Center Continuous Rating2750 kW / 3438 kVA
Prime Rating2750 kW / 3438 kVA
Continuous Rating2500 kW / 3125 kVA
Voltage277/480V
Phase3-Phase
Frequency60 Hz
Emissions ConfigurationEPA Tier 2
EnclosureSound Attenuated
Fuel Tank6,000-gallon UL142 sub-base tank with secondary containment
ConditionNew
AvailabilityIncoming Fall 2027

Large Generator Capacity for Demanding Critical-Power Applications

The C3000D6E can be evaluated for projects requiring large-scale standby or data center generator capacity, including:

Cummins specifically publishes a Data Center Continuous rating of 2750 kW for the C3000D6E, making that rating particularly relevant when engineering teams evaluate the unit for data-center applications.

New Cummins C3000D6E QSK95 G9 Diesel Generator 2

Planning a Multi-Unit Generator Project?

Scale Capacity Across Multiple 3 MW Generator Sets

Large data centers and critical facilities often require multiple generator sets to support facility load, redundancy and future expansion.

Multi-unit planning should consider required capacity, redundancy objectives, electrical blocks, phased expansion, maintenance requirements and the generator/switchgear architecture.

Generator Capacity Infographic

For projects using multiple C3000D6E units, generator controls, paralleling equipment, switchgear, transfer equipment and distribution need to be engineered around the intended operating sequence.

Coordinate Generator Sourcing With the Project Schedule

Generator procurement needs to align with the broader data center construction or expansion schedule. Equipment selection may need to be coordinated with electrical engineering, permitting, fuel-system design, site preparation, switchgear, transfer equipment, freight, rigging and commissioning.

Identifying suitable equipment early allows engineering and construction teams to evaluate the proposed generators as part of the complete electrical design.

Generator Capacity Is Only Part of the Data Center Power System

Coordinate Generators With the Complete Critical-Power Infrastructure

A data center generator does not operate independently from the UPS systems and electrical distribution supporting the facility.

Large critical-power projects may also need to coordinate:

UPS Systems

Provide immediate support to protected loads and bridge the transition between normal and alternate power sources.

Automatic Transfer Switches

Coordinate the transfer of designated loads between normal and alternate electrical sources.

Data Center Power Infrastructure

Plan UPS capacity, generators, redundancy, temporary power and other critical-power requirements together.

Planning Generator Capacity for AI & GPU Infrastructure

Supporting High-Density Data Center Expansion

AI and GPU deployments can materially increase a facility’s electrical load, making existing generator, UPS and distribution capacity important parts of expansion planning.

Before adding significant computing capacity, project teams should review:

  • Existing and planned critical load
  • Available generator capacity
  • UPS capacity and battery runtime
  • Redundancy requirements
  • Transfer and distribution equipment
  • Cooling infrastructure
  • Planned growth

For additional planning guidance

What to Confirm for a 3 MW Generator Project

Before selecting generator equipment, establish:

  • Required standby, prime or data center continuous capacity
  • Number of generator sets required
  • Required voltage
  • Phase and frequency
  • Facility load
  • Redundancy requirements
  • Fuel and runtime requirements
  • Emissions and permitting requirements
  • Generator placement
  • Enclosure requirements
  • Fuel-tank configuration
  • Switchgear and paralleling requirements
  • Automatic transfer equipment
  • Generator-to-UPS coordination
  • Installation schedule
  • Delivery and rigging requirements

Already have a generator specification or electrical one-line?

Send CI Group your project requirements so our team can compare them with the incoming C3000D6E equipment.

Related Generator Planning Resources

How to Source Large-Scale Generators for Data Center Build-Outs

Capacity, ratings, voltage, emissions, equipment condition and project-timing considerations for large generator projects.

Used vs. New Generators: Cost & Buying Guide

Compare generator equipment based on total installed cost, configuration, availability, warranty, testing and support.

Backup Power Planning for Utility Outages

Learn how generators, UPS systems, ATS equipment, fuel and electrical distribution work together.

Planning a Multi-Megawatt Generator Project?

CI Group can help evaluate the incoming Cummins C3000D6E generator sets against your required capacity, voltage, operating profile, project schedule and critical-power requirements.

Whether you need one 3 MW generator or multiple units for a larger installation, send us your project specifications and equipment requirements.

New Equipment | 3000 kW Standby | 277/480V | Incoming Fall 2027